The first OPC standard specification resulted from the collaboration of a number of leading worldwide automation suppliers working in cooperation with Microsoft. Interoperability is assured through the creation and maintenance of non-proprietary open standards specifications. OPC is open connectivity in industrial automation and the enterprise systems that support the industry. Interoperability, open solutions, and freedom of choice have helped automation professionals around the globe realize the advantages of incorporating OPC into their industrial applications. This is an exciting time in the industry. OPC has helped automation suppliers provide solutions that are truly open, which in turn has given users more choices in their automation applications. OPC has led to improved cooperation between technology providers and users alike.
#Kepserverex server 2012 software
Even when the hardware and software are from different vendors, OPC compliance makes continuous real-time communication possible. OPC is a widely accepted industrial communication standard that enables the exchange of data between multi-vendor devices and control applications without any proprietary restrictions. | Runtime host address = '', User = '', Reason = ''.One application acts as the server providing data, and the other acts as a client using data. | User = ''.Ĭonnection attempt to runtime failed. | Administrator name = '', Current user = ''.
#Kepserverex server 2012 windows
Current user is not a Windows administrator.
#Kepserverex server 2012 password
| Group = ''.įailed to reset password for administrator. Permissions definition has changed on user group. | User = '', Old group = '', New group ''. Password for administrator was reset by the current user. The invalid ProgID entry has been deleted from the ProgID Redirect list. OPC ProgID has been removed from the ProgID Redirect list. OPC ProgID has been added to the ProgID Redirect list. Shutting down to perform an installation. | Phone Number Name = '', Updated Priority = ''.Īccess to object denied. The project file was created with a more recent version of this software.Ī client application has disabled auto-demotion on device ''. Simulation mode is disabled on device ''.Īttempting to automatically generate tags for device ''.Ĭompleted automatic tag generation for device ''.Ī client application has enabled auto-demotion on device ''.ĭata collection is disabled on device ''.ĭevice '' has been auto-promoted to determine if communications can be reestablished.įailed to read build manifest resource. TAPI configuration has changed, reinitializing. | Channel = ''.Ĭhannel requires Auto-Dial enabled and at least one number in its phonebook to use a shared modem connection. Defaulting the time zone to ''.Ĭhannel requires at least one number in its phonebook for automatic dialing. This is not a valid time zone for the system.
#Kepserverex server 2012 driver
The '' driver does not currently support XML persistence. Unable to apply modem configuration on line ''.ĭevice '' has been automatically demoted. Validation error on '': Invalid scaling parameters. Using default network adapter.212 Rejecting attempt to change model type on a referenced device ''. Unable to use network adapter '' on channel ''. No comm handle provided on connect for line ''. Unable to generate a tag database for device '':Īuto generation produced too many overwrites, stopped posting error messages.įailed to add tag '' because the address is too long.

Unable to generate a tag database for device ''. | Object = ''.Īuto-generated tag '' already exists and will not be overwritten. 209 Unable to load the project due to a missing object. To load XML projects, change the product language selection to English in Server Administration. The current language does not support loading XML projects. was not found or could not be loaded.ĭevice discovery has exceeded maximum allowed devices. Project without a backup, deselect the backup option under Tools | Options | General and resave the project. Verify the destination file is not locked and has read/write access. Unable to add device due to driver-level failure. Unable to add channel due to driver-level failure. Remove the conflicting driver and restart the application.įailed to open modem line ''. Unable to load the '' driver because more than one copy exists ('' and ''). The device driver was not found or could not be loaded.

IFIX Signal Conditioning Options Project Startup for iFIX Applications Work with Non-Normalized Floating Point Values Resolve Comm Issues When the DNS/DHCP Device Connected to the Server is Power Cycled Properly Name a Channel, Device, Tag, and Tag Group
#Kepserverex server 2012 serial
Channel Properties - Ethernet CommunicationsĬhannel Properties - Serial CommunicationsĬhannel Properties - Ethernet EncapsulationĬhannel Properties - Communication Serializationĭevice Properties - Communication Parametersĭevice Properties - Ethernet Encapsulation